Three Phase Separator Sizing

Three Phase Vertical Separators Sizing

As with vertical two-phase separators, a minimum diameter must be  maintained to assure adequate gas capacity. In addition, vertical threephase  separators must maintain a minimum diameter to allow the 500 micron water droplets to settle. The height of the three-phase separator is  determined from retention time considerations.

Gas Capacity
The gas capacity constraints provide the following formula

Settling
The [...]

14Sep2009 | admin | Comments Off | Continued

Three Phase Horizontal Separator Sizing

For sizing a horizontal three-phase separator it is necessary to specify a vessel diameter and a seam-to-seam vessel length. The gas capacity and retention time considerations establish certain acceptable combinations of diameter and length. The need to settle 500-micron water droplets
from the oil establishes a maximum diameter.
Gas Capacity
The gas capacity constraints provide the following formula,

Retention [...]

14Sep2009 | admin | Comments Off | Continued