<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Surface Production Facility &#187; Treating Equipment</title>
	<atom:link href="http://www.process-facility.com/category/oil-handling-surfacefacilities/crude-oil-treating-system/treating-equipment.html/feed" rel="self" type="application/rss+xml" />
	<link>http://www.process-facility.com</link>
	<description>Oil and Gas Production Facility Design</description>
	<lastBuildDate>Fri, 14 May 2010 03:34:57 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=abc</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>Electrostatic Treaters</title>
		<link>http://www.process-facility.com/electrostatic-treaters.html</link>
		<comments>http://www.process-facility.com/electrostatic-treaters.html#comments</comments>
		<pubDate>Wed, 02 Sep 2009 03:15:23 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Treating Equipment]]></category>
		<category><![CDATA[Coalescence]]></category>
		<category><![CDATA[electrostatic treaters]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=481</guid>
		<description><![CDATA[




Some treaters use an electrode section. Figure 6-11 illustrates a typical design of a horizontal electrostatic treater. The flow path in an electrostatic treater is the same as a horizontal treater. The only difference is that an AC and/or DC electrostatic field is used to promote coalescence of the water droplets.
 Procedures for designing electrostatic [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/electrostatic-treaters.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Horizontal Treaters</title>
		<link>http://www.process-facility.com/horizontal-treaters.html</link>
		<comments>http://www.process-facility.com/horizontal-treaters.html#comments</comments>
		<pubDate>Tue, 01 Sep 2009 22:11:55 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Treating Equipment]]></category>
		<category><![CDATA[Horizontal Treaters]]></category>
		<category><![CDATA[Treaters]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=473</guid>
		<description><![CDATA[




For most multi-well situations horizontal treaters are normally required. Figure 6-10 shows a typical design of a horizontal treater.
Flow enters the front section of the treater where gas is flashed. The liquid falls around the outside to the vicinity of the oil-water interface where the liquid is &#8220;water washed&#8221; and the free water is separated. [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/horizontal-treaters.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Vertical Treaters</title>
		<link>http://www.process-facility.com/vertical-treaters.html</link>
		<comments>http://www.process-facility.com/vertical-treaters.html#comments</comments>
		<pubDate>Tue, 01 Sep 2009 21:55:18 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Treating Equipment]]></category>
		<category><![CDATA[free-water knockout]]></category>
		<category><![CDATA[gunbarrels]]></category>
		<category><![CDATA[Treaters]]></category>
		<category><![CDATA[Vertical Treaters]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=467</guid>
		<description><![CDATA[




The most commonly used single-well lease treater is the vertical treater as shown in Figure 6-8. Flow enters the top of the treater into a gas separation section. Care must be exercised to size this section so that it has adequate dimensions to separate the gas from the inlet flow. If the treater is located [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/vertical-treaters.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>