<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Surface Production Facility &#187; LTX Units and Line Heaters</title>
	<atom:link href="http://www.process-facility.com/category/gas-production-facility/ltx-units-and-line-heaters.html/feed" rel="self" type="application/rss+xml" />
	<link>http://www.process-facility.com</link>
	<description>Oil and Gas Production Facility Design</description>
	<lastBuildDate>Fri, 14 May 2010 03:34:57 +0000</lastBuildDate>
	<generator>http://wordpress.org/?v=abc</generator>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
			<item>
		<title>LTX Coil Sizing – Coil Lengths</title>
		<link>http://www.process-facility.com/ltx-coil-sizing-coil-lengths.html</link>
		<comments>http://www.process-facility.com/ltx-coil-sizing-coil-lengths.html#comments</comments>
		<pubDate>Wed, 16 Sep 2009 11:23:29 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Coil Sizing]]></category>
		<category><![CDATA[LTX Units]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=1208</guid>
		<description><![CDATA[




With the known temperatures on each end of the coil, the heat duty for each coil can be calculated from the heat transfer theory. Since the bath is at a constant temperature, LMTD can be calculated as:


The overall film coefficient, U, for the coil can be calculated or read from the charts and tables in [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/ltx-coil-sizing-coil-lengths.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>LTX Coil Sizing &#8211; Choose Wall Thickness</title>
		<link>http://www.process-facility.com/ltx-coil-sizing-choose-wall-thickness.html</link>
		<comments>http://www.process-facility.com/ltx-coil-sizing-choose-wall-thickness.html#comments</comments>
		<pubDate>Wed, 16 Sep 2009 11:13:02 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Coil Sizing]]></category>
		<category><![CDATA[LTX Units]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=1203</guid>
		<description><![CDATA[




Before choosing a wall thickness it is necessary to choose a pressure rating for the coil. Typically, the high-pressure coil (L1) is rated for the shut-in pressure of the well, and the low-pressure coil (L2) is rated for the maximum working pressure of the downstream equipment. There are many exceptions to this rule and reasons [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/ltx-coil-sizing-choose-wall-thickness.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>LTX Coil Sizing &#8211; Choose Coil Diameter</title>
		<link>http://www.process-facility.com/ltx-coil-sizing-choose-coil-diameter.html</link>
		<comments>http://www.process-facility.com/ltx-coil-sizing-choose-coil-diameter.html#comments</comments>
		<pubDate>Wed, 16 Sep 2009 10:52:08 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Coil Sizing]]></category>
		<category><![CDATA[LTX Units]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=1197</guid>
		<description><![CDATA[




Erosional flow criteria will almost always govern in choosing the diameter. Sometimes it is necessary to
check for pressure drop in the coil. Typically, pressure drop will not be important since the whole purpose of the line heater is to allow a large pressure drop that must be taken. The allowable erosional velocity is given by:


The [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/ltx-coil-sizing-choose-coil-diameter.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>LTX Coil Sizing &#8211; Choose Temperatures</title>
		<link>http://www.process-facility.com/ltx-coil-sizing-choose-temperatures.html</link>
		<comments>http://www.process-facility.com/ltx-coil-sizing-choose-temperatures.html#comments</comments>
		<pubDate>Wed, 16 Sep 2009 10:42:19 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Coil Sizing]]></category>
		<category><![CDATA[LTX Units]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=1195</guid>
		<description><![CDATA[In order to choose the coil length and diameter, a temperature must first be chosen upstream of the choke; the higher Th the longer the coil L] and the shorter the coil L2. In Heat Transfer Theory we showed that the greater the LMTD between the gas and the bath temperature, the greater the heat [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/ltx-coil-sizing-choose-temperatures.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Fire Tube Size</title>
		<link>http://www.process-facility.com/fire-tube-size.html</link>
		<comments>http://www.process-facility.com/fire-tube-size.html#comments</comments>
		<pubDate>Wed, 16 Sep 2009 08:45:30 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[LTX Units and Line Heaters]]></category>
		<category><![CDATA[LTX Units]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=1190</guid>
		<description><![CDATA[The area of the fire tube is normally calculated based on a heat flux rate of 10,000 Btu/hr-ft2. The fire-tube length can be determined from:


where L = fire tube length, ft
q = total heat duty, Btu/hr
d = fire tube diameter, in.
A burner must be chosen from the standard sizes in Table 2-12, For example, if [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/fire-tube-size.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>LTX Units Heat Duty</title>
		<link>http://www.process-facility.com/ltx-units-heat-duty.html</link>
		<comments>http://www.process-facility.com/ltx-units-heat-duty.html#comments</comments>
		<pubDate>Tue, 15 Sep 2009 11:00:15 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[LTX Units and Line Heaters]]></category>
		<category><![CDATA[LTX Units]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=1078</guid>
		<description><![CDATA[To calculate the heat duty it must be remembered that the pressure drop through the choke is instantaneous. That is, no heat is absorbed or lost, but there is a temperature change. This is an adiabatic expansion of the gas with no change in enthalpy. Flow through the coils is a constant
pressure process, except for [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/ltx-units-heat-duty.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Line Heaters</title>
		<link>http://www.process-facility.com/line-heaters.html</link>
		<comments>http://www.process-facility.com/line-heaters.html#comments</comments>
		<pubDate>Tue, 15 Sep 2009 10:46:24 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[LTX Units and Line Heaters]]></category>
		<category><![CDATA[Line Heaters]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=1073</guid>
		<description><![CDATA[As shown in Figure 5-2, the wellstream enters the first coil at its flowing tubing temperature and pressure. Alternatively, it could be choked at the wellhead to a lower pressure, as long as its temperature remains above hydrate temperature.
There is typically a high-pressure coil of length L1, which heats the wellstream to temperature, T1. The [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/line-heaters.html/feed</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>LTX Units</title>
		<link>http://www.process-facility.com/ltx-units.html</link>
		<comments>http://www.process-facility.com/ltx-units.html#comments</comments>
		<pubDate>Tue, 15 Sep 2009 09:29:11 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[LTX Units and Line Heaters]]></category>
		<category><![CDATA[LTX Units]]></category>

		<guid isPermaLink="false">http://www.process-facility.com/?p=1069</guid>
		<description><![CDATA[These units are designed to allow hydrates to form and to melt them with the heat of the incoming gas stream before they can plug downstream equipment. In addition, the low-temperature separation that
occurs in an LTX unit results in stabilizing the liquids. This results in an increase in liquids recovered and a corresponding decrease in [...]]]></description>
		<wfw:commentRss>http://www.process-facility.com/ltx-units.html/feed</wfw:commentRss>